MCCB SIEMENS
-
MCCB 55KA 40A: 3VL1704-1DD33-0AA0
CIRCUIT-BREAKER VL160X N
STANDARD BREAKING CAPACITY
ICU=55KA / 415 V AC
3 POLE, LINE PROTECTION
OVERCURRENT RELEASE
TM, LI
IN=40A, RATED CURRENT
IR=32-40A, OVERLOAD
II=600A, SHORT-CIRCUIT
WITHOUT AUXILIARY RELEASE
WITHOUT AUXILIARY/ALARM SWITCH
Xem thêm0,00 ₫ -
MCCB 55KA 32A: 3VL1703-1DD33-0AA0
CIRCUIT-BREAKER VL160X N
STANDARD BREAKING CAPACITY
ICU=55KA / 415 V AC
3 POLE, LINE PROTECTION
OVERCURRENT RELEASE
TM, LI
IN=32A, RATED CURRENT
IR=25-32A, OVERLOAD
II=300A, SHORT-CIRCUIT
WITHOUT AUXILIARY RELEASE
WITHOUT AUXILIARY/ALARM SWITCH
Xem thêm0,00 ₫ -
MCCB, 4P, In = 25A, Icu = 55kA: 3VL1725-1EH43-0AA0
"CIRCUIT-BREAKER VL160X N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=25A, RATED CURRENT IR=25A, OVERLOAD II=300A, SHORT-CIRCUIT N NOT PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH"
Xem thêm0,00 ₫ -
MCCB, 4P, In = 32A, Icu = 55kA: 3VL1703-1EH43-0AA0
"CIRCUIT-BREAKER VL160X N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=32A, RATED CURRENT IR=32A, OVERLOAD II=300A, SHORT-CIRCUIT N NOT PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH"
Xem thêm0,00 ₫ -
MCCB, 3P, In = 50A, Icu = 55kA: 3VL2705-1DC33-0AA0
"CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=40-50A, OVERLOAD II=300-600A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH"
Xem thêm0,00 ₫ -
MCCB 55KA 20A: 3VL1702-1DD33-0AA0
CIRCUIT-BREAKER VL160X N
STANDARD BREAKING CAPACITY
ICU=55KA / 415 V AC
3 POLE, LINE PROTECTION
OVERCURRENT RELEASE
TM, LI
IN=20A, RATED CURRENT
IR=16...20A, OVERLOAD
II=300A, SHORT-CIRCUIT
WITHOUT AUXILIARY RELEASE
WITHOUT AUXILIARY/ALARM SWITCH
Xem thêm0,00 ₫ -
MCCB, 4P, In = 160A, Icu = 55kA: 3VL2716-1EJ43-0AA0
"CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=160A, RATED CURRENT IR=125-160A, OVERLOAD II=800-1600A, SHORT CIRCUIT N NOT PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH"
Xem thêm0,00 ₫ -
MCCB, 4P, In = 125A, Icu = 55kA: 3VL2712-1EJ43-0AA0
"CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=125A, RATED CURRENT IR=100-125A, OVERLOAD II=625-1250A, SHORT CIRCUIT N NOT PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH"
Xem thêm0,00 ₫ -
MCCB, 4P, In = 100A, Icu = 55kA: 3VL2710-1EJ43-0AA0
"CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=100A, RATED CURRENT IR=80-100A, OVERLOAD II=500-1000A, SHORT CIRCUIT N NOT PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH"
Xem thêm0,00 ₫ -
MCCB, 4P, In = 80A, Icu = 55kA: 3VL2708-1EJ43-0AA0
"CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=80A, RATED CURRENT IR=63-80A, OVERLOAD II=400-800A, SHORT CIRCUIT N NOT PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH"
Xem thêm0,00 ₫